Getting live controller data from a PLC or DCS into Excel for analysis has always required a workaround — OPC Expert bridges that gap by connecting OPC servers directly to Excel for both real-time reads and writes and historical reporting.
Setting OPC Connections to Read-Only to Prevent Writes
Can an OPC Connection Be Set to Read-Only to Prevent Users from Writing to the End Device? OPC Expert supports read-only access configurations that prevent writes from reaching the connected
Send Email Alerts When an OPC Value Drops Below a Threshold
How to Configure OPC Expert to Send Email Alerts When a Value Drops Below a Threshold OPC Expert supports automated email notifications triggered by OPC data conditions, including value threshold
Saving OPC Excel Configuration Across File Close and Reopen
How OPC Excel Configurations Persist When the Workbook Is Closed and Reopened OPC Expert saves OPC configuration and query definitions within the Excel workbook file itself. When the workbook is
Real-Time vs. Historical OPC Data in Excel: Key Differences
Working with Real-Time vs. Historical OPC Data in Excel: What Changes? OPC Expert delivers both real-time and historical OPC data into Excel, but the two modes behave differently and serve
How to Retrieve OPC Variable Engineering Units in Excel
How to Retrieve OPC Variable Engineering Units When Pulling Data into Excel OPC tags carry metadata properties beyond their numeric value, and engineering units are one of those properties. Whether
Does OPC Expert Need to Be on the Same PC as the OPC Server?
Do OPC Expert and Excel Need to Be on the Same Computer as the OPC Server? OPC Expert and Excel do not need to be on the same computer as
OPC UA Security Features: Encryption and Authentication
What Security Features Does OPC UA Offer for Industrial Communication? OPC UA incorporates security at the protocol level, making it fundamentally different from OPC Classic which relied on Windows DCOM
OPC Data Archiving: Performance, Volume, and Compression
OPC Data Archiving: Storage Volume, Performance Impact, and Compression OPC Expert’s archiving capability is limited in practice by the available disk space and database capacity of the chosen storage target
OPC Redundancy: Automatic Failover to a Backup Server
OPC Redundancy: Automatic Failover to a Backup OPC Server for SCADA OPC Expert supports redundant OPC server configurations where two servers, one primary and one standby, are monitored simultaneously. When
Running an OPC DA Client Inside a Virtual Machine
Can You Run an OPC DA Client Inside a Virtual Machine? Running an OPC DA client inside a virtual machine is technically supported, but the virtualized network environment requires specific